From system design to predictive maintenance, our engineering team supports every stage of your compressor lifecycle.
Our application engineers collaborate with your team to select the optimal compressor type, capacity, and refrigerant for your specific operating conditions. We provide thermal load calculations, P&ID review, and integration guidance for new builds and retrofits.
Our field service engineers supervise installation, perform system evacuation, charge verification, and comprehensive commissioning testing. Every unit is validated against manufacturer specifications before handover, with full documentation provided.
Combine scheduled preventive maintenance with IoT-driven predictive analytics. Our connected maintenance platform monitors compressor health in real time, scheduling interventions before failures occur, reducing downtime and extending equipment service life.
Transition existing compressor installations to low-GWP refrigerants, add VFD capability to fixed-speed units, or upgrade control systems for BMS integration. Our retrofit team minimizes disruption while maximizing performance improvement.
On-site and virtual training programs for your maintenance technicians and system operators. Courses cover compressor operation, refrigerant handling, VFD tuning, IoT platform usage, and safety compliance procedures.
When critical compressor systems fail, every hour counts. Our emergency service network provides rapid-response technical support with targeted response times based on your service level agreement and geographic location.
Our service programs cover the following compressor types and capacity ranges. For equipment outside these parameters, contact our engineering team for case-by-case evaluation.
| Compressor Type | Capacity Range | Refrigerants Covered | Service Level Available |
|---|---|---|---|
| Screw (semi-hermetic) | 30 kW – 800 kW | R-134a, R-513A, R-1234ze, R-744, R-449A | Preventive, Predictive, Emergency |
| Scroll | 3 kW – 120 kW | R-410A, R-32, R-290, R-454B | Preventive, Emergency |
| Reciprocating (semi-hermetic) | 5 kW – 150 kW | R-404A, R-448A, R-449A, R-744 | Preventive, Predictive, Emergency |
| VFD Packages | 15 kW – 800 kW | All supported refrigerants | Preventive, Predictive (incl. drive diagnostics) |
Preventive maintenance intervals: screw compressors every 4,000 operating hours or 12 months (whichever comes first); scroll compressors every 6,000 hours or 18 months. Predictive monitoring requires an active IoT connectivity subscription.
Our service team is ready to discuss your maintenance, retrofit, or new project requirements.
Contact Our Service Team